Back to Resources
MCS-SPEC-02Commercial

Commercial Concrete

Higher-strength mixes, engineered reinforcement & code-compliant placement.

Scope Overview

Reliable, professional concrete work designed to meet the performance and durability demands of commercial properties — including slabs, walkways, curbs, and loading areas engineered for higher traffic and code compliance.

Technical Specification

Specification Details

01

Material & Mix Specification

ParameterSpecification
Concrete MixReady-mix, 4,000–5,000 psi @ 28 days (per design)
Slump4 in ± 1 in (with water-reducing admixture)
Reinforcement#4 rebar @ 16 in O.C. E.W. or designed mat (per structural)
Air Entrainment4%–6% (exterior exposure)
Coarse Aggregate3/4 in – 1 in max
02

Execution & Tolerances

ParameterSpecification
SubgradeCompacted to 95% SPD; proof-rolled per engineer
Slab Thickness5–6 in per loading & design
FinishBroom (exterior) / trowel (interior) per spec
Slope / Drainage1/4 in per ft min; 1% min for ADA paths
JointsControl & construction joints per structural layout
CuringCuring compound or wet cure, 7 days
03

Quality Assurance & Acceptance

  • Mix designs and delivery tickets reviewed against approved submittal.
  • Placement, finishing, and joint layout inspected per approved plans.
  • Compressive-strength test cylinders cast per ACI sampling frequency.
  • Compliance with local codes and accessibility requirements verified prior to sign-off.

Need this spec tailored to your project?

These sheets are our standard baseline. For project-specific specifications and a detailed estimate, send us your project details.