Back to Resources
MCS-SPEC-02Commercial
Commercial Concrete
Higher-strength mixes, engineered reinforcement & code-compliant placement.
Scope Overview
Reliable, professional concrete work designed to meet the performance and durability demands of commercial properties — including slabs, walkways, curbs, and loading areas engineered for higher traffic and code compliance.
Technical Specification
Specification Details
01
Material & Mix Specification
| Parameter | Specification |
|---|---|
| Concrete Mix | Ready-mix, 4,000–5,000 psi @ 28 days (per design) |
| Slump | 4 in ± 1 in (with water-reducing admixture) |
| Reinforcement | #4 rebar @ 16 in O.C. E.W. or designed mat (per structural) |
| Air Entrainment | 4%–6% (exterior exposure) |
| Coarse Aggregate | 3/4 in – 1 in max |
02
Execution & Tolerances
| Parameter | Specification |
|---|---|
| Subgrade | Compacted to 95% SPD; proof-rolled per engineer |
| Slab Thickness | 5–6 in per loading & design |
| Finish | Broom (exterior) / trowel (interior) per spec |
| Slope / Drainage | 1/4 in per ft min; 1% min for ADA paths |
| Joints | Control & construction joints per structural layout |
| Curing | Curing compound or wet cure, 7 days |
03
Quality Assurance & Acceptance
- Mix designs and delivery tickets reviewed against approved submittal.
- Placement, finishing, and joint layout inspected per approved plans.
- Compressive-strength test cylinders cast per ACI sampling frequency.
- Compliance with local codes and accessibility requirements verified prior to sign-off.
Need this spec tailored to your project?
These sheets are our standard baseline. For project-specific specifications and a detailed estimate, send us your project details.